VTC-5600
Sanyo 1980
Betamax VTC-5600



beta vcr logo

Technical

No technical information is available for this model at the moment. Are you able to supply PALsite with more information?

Quick fault guide

Please click on the button if you are able to contribute a solution to this list or would like to add to, or update PALsite's information on this model. Please note, questions will be removed.

If you have a question about this model, please raise it on the chatpage.

FaultSolution
Loss of head drum speed lock, unstable pictureAdjust VR404 (drum free run speed) on the servo board until you get a perfect picture. Replacing the capacitors is recommended.
Garbled test signal patternConnect the unit to an analog TV via the RF output, set the test signal switch to ON and adjust VR124 (test signal oscillator frequency) on the W1 board until the pattern is stable.